COMPARTMENTING AND FIRE PROOFING SEALINGS
PM 028 - MANSORY WALL
BUILDING JOINT
SPECIFICATION
KM SEALER 2GE156 is made up of a mineral fibre wool insert with graphitic
thermo- expandable gasket KM-FF107
FITTING UP
The strip KM SEALER 2GE156 is inserted, compressing it, into the opening of building joint. The thermo-expandable gasket must be in contact with one of the two sides of the joint.
Suitable for 130 mm building joints
CERTIFICATION
-
Istituto Giordano 280628/3283 FR, pos.G.